17
2.3 Auto setup
The SDS1000 Series Digital Storage Oscilloscopes has a Auto Setup function that
identifies the waveform types and automatically adjusts controls to produce a usable
display of the input signal.
Press the AUTO front panel button, and then press the menu option button adjacent to
the desired waveform as follows:
Picture 2-3
Table 2-1 Auto Set function Menu:
Option Description
(Multi-cycle sine)
Auto set the screen and display
several cyc signal.
(Single-cycle sine)
Set the screen and auto display
single cyc signal.
(Rising edge)
Auto set and show the rising time.
(Falling edge)
Auto set and show the falling time.
(Undo Setup)
Causes the oscilloscope to recall
the previous setup.
Auto set determines the trigger source based on the following conditions:
●
If multiple channels have signals, channel with the lowest frequency signal.
●
No signals found, the lowest-numbered channel displayed when Auto set was invoked